Emerson Process Management rosemount 3300 series manual 5525066$*6, $/$50$15,7 3527&7,21

Models: rosemount 3300 series

1 128
Download 128 pages 23.28 Kb
Page 70
Image 70
SWITCH_WRP_ALARM_DISPLAY

 

5HIHUHQFH￿0DQXDO

Rosemount 3300 Series

00809-0100-4811, Rev AA

October 2002

(5525￿0(66$*(6

The display can alos be used for presentation of software errors. The upper

 

row shows error codes and the lower row shows ’ERROR’.

Figure 5-2. Presentation of error

 

￿￿￿￿￿￿￿￿￿￿

messages

 

 

 

L￿￿￿)￿2

 

 

ERRORDISPLAY

 

The￿￿￿￿following￿￿￿￿￿errors can be displayed:

 

CNFIG

Invalid Configuration

 

00001

Ram Failure

 

00002

ROM Checksum

 

00006

Waveform Acquisition Failure

 

00007

EEprom Factory Checksum

 

00010

Software Error

 

00013

Probe Failure

$/$50￿$1'￿:5,7(￿ 3527(&7,21

Figure 5-3. Alarm and Write Protection switches.

See also “Errors.” on page 6-20.

When mounting the Integral Display panel it is important that*￿￿￿￿￿;￿￿￿￿the Alarm and Write Protection switches on the transmitter mother board are correctly set.

Make sure that the Alarm switch is in the HIGH position and the Write Protection switch is in the OFF position, see Figure 5-3.See also 6HFWLRQ ￿￿￿

%HIRUH￿<RX￿,QVWDOO for more information.

Once the mother board positions are set, then the display positions become the master.

5-2