Emerson Process Management rosemount 3300 series UHH6SDFH, Recommended free space to tank wall

Models: rosemount 3300 series

1 128
Download 128 pages 23.28 Kb
Page 29
Image 29

5HIHUHQFH￿0DQXDO￿

00809-0100-4811, Rev AA October 2002

Rosemount 3300 Series

)UHH￿6SDFH

For easy access to the transmitter make sure that it is mounted with sufficient

 

service space. For maximum measurement performance the transmitter

 

should not be mounted too close to the tank wall or other objects in the tank.

 

If the probe is mounted close to a wall, nozzle or other tank obstruction noise

 

might appear in the level signal. Therefore the following minimum clearance,

 

according to the table below, must be maintained:

Figure 3-5. Free Space

 

 

 

 

 

 

 

 

 

 

 

Requirement

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FREE SPACE

Table 3-5. Recommended free space to tank wall

&RD[LDO

5LJLG￿7ZLQ

)OH[LEOH￿7ZLQ

5LJLG￿6LQJOH

)OH[LEOH￿6LQJOH

 

 

 

 

 

0 in. (0 mm)

4 in. (100 mm)

4 in. (100 mm)

12 in. (300 mm)

12 in. (300 mm)

 

 

 

 

 