Emerson Process Management rosemount 3300 series manual Rosemount 3300 Series

Models: rosemount 3300 series

1 128
Download 128 pages 23.28 Kb
Page 94
Image 94

Rosemount 3300 Series

5HIHUHQFH￿0DQXDO

00809-0100-4811, Rev AA October 2002

 

 

Probes

Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).

 

Rigid Twin Lead: 2 ft (0.6 m) to 9.8 ft (3 m).

 

Flexible Twin Lead: 3.3 ft (1 m) to 65.6 ft (20 m).

 

Rigid Single Lead: 2 ft (0.6 m) to 9.8 ft (3 m).

 

Flexible Single Lead: 3.3 ft (1 m) to 65.6 ft (20 m).

 

For further information see “Ordering Information” on page A-8.

 

 

Material exposed to tank atmosphere

316/316L SST (EN 1.4404), Teflon (PTFE, PFA) and O-ring materials (see

 

ordering information).

Dimensions

See “Dimensional drawings” on page A-3.

 

 

Probe angle

0 to 90 degrees from vertical axis.

Housing / Enclosure

Polyurethane-covered Aluminium.

 

 

Flanges, Threads

See “Ordering Information” on page A-8.

Height above flange

See “Dimensional drawings” on page A-3.

 

 

 

 

 

 

Ambient temperature

-40 °F to +185 °F ( -40 °C to +85 °C), depends on approval (see App. B).

 

For the LCD display the temperature range is

 

-4 °F to +185 °F (-20 °C to +85 °C).

 

 

Process temperature

-40 °F to +302 °F ( -40 °C to +150 °C).

Process pressure

Full vacuum to 580 psig ( -1 to 40 Bar).

 

 

Humidity

0 - 100 % relative humidity

Ingress protection

NEMA 4X, IP 66.

 

 

Telecommunication (FCC and R&TTE)

FCC part 15 (1998) subpart B and R&TTE (EU directive 97/23/EC).

Factory sealed

Yes.

 

 

Vibration resistance

DIN EN 60068-2-64, IEC 68-2-64, ANSI/ISA-571.03 SA1, VC2.

Electromagnetic compatibility

Emission and Immunity: meets EN 61326-1 (1997) and amendment A1,

 

class A equipment intended for use in industrial locations if installed in

 

metallic vessels or still-pipes.

 

When rigid/flexible single and twin lead probes are installed in plastic or

 

wood silos influence of strong electromagnetic fields might affect

 

measurements.

 

 

Built-in Lightning Protection

Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4.

Pressure Equipment Directive (PED)

Complies with 97/23/EC article 3.3 (confirmed by DNV).

 

 

Ordinary Location FM 3810,

Compliance.

Boiler Approval CSA B51-97

Compliance.

 

 

 

 

 

 

Reference accuracy

± 0.2 inch (5 mm) for probes 16.4 ft (5 m) and

 

± 0.1% of measured distance for probes >16.4 ft (5 m).

 

 

Repeatability

± 0.04 inch (1 mm).

Ambient Temperature Effect

Less than 0.01 % of measured distance per °C.

 

 

Update interval

1 per second

Measuring range

8 inch (0.1 m) to 65 ft (20 m).

 

 

A-2