Roland VC-1 D-50 owner manual Midi Implementation, Data Transmission

Models: VC-1 D-50

1 100
Download 100 pages 61.9 Kb
Page 88
Image 88

MIDI Implementation

Model:VC-1

Date:

January 10, 2005

Version:1.10

1. Data Transmission

Channel Voice Messages

Control Change

Bank Select (Controller number 0, 32)

Status

2nd byte

3rd byte

BnH

00H

mmH

BnH

20H

llH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm, ll = Bank number:

00 00H - 7F 7FH (bank.1 - bank.16384)

*Not transmitted when Bank Select Switch (SYSTEM MIDI) is OFF.

*The Patches corresponding to each Bank Select are as follows.

BANK

 

 

 

SELECT

 

 

 

 

 

PROGRAM

BATCH

PATCH

MSB

LSB

NUMBER

BANK

NUMBER

 

 

 

 

 

 

 

 

000

001 - 064

Internal 1

11 - 88

 

001

001 - 064

Internal 2

11 - 88

 

002

001 - 064

Internal 3

11 - 88

 

003

001 - 064

Internal 4

11 - 88

 

004

001 - 064

Internal 5

11 - 88

 

005

001 - 064

Internal 6

11 - 88

087

006

001 - 064

Internal 7

11 - 88

007

001 - 064

Internal 8

11 - 88

 

 

008

001 - 064

Preset 1

11 - 88

 

009

001 - 064

Preset 2

11 - 88

 

010

001 - 064

Preset 3

11 - 88

 

011

001 - 064

Preset 4

11 - 88

 

012

001 - 064

Preset 5

11 - 88

 

013

001 - 064

Preset 6

11 - 88

*The transmitted value of MSB can be changed by Tx Bank Select (Patch MIDI).

*In that case the transmitted value of LSB is always 0.

Portamento Switch (Controller number 65)

Status

2nd byte

3rd byte

BnH

41H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Control value:

00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON

Program Change

Status

2nd byte

 

CnH

ppH

 

n = MIDI channel number:

0H - FH (ch.1 - 16)

pp = Program number:

00H - 3FH (prog.1 - prog.64)

*Not transmitted when Program Change Switch (SYSTEM MIDI) is OFF.

System Realtime Messages

Active Sensing

Status

FEH

*This message is transmitted at intervals of approximately 250 msec.

System Exclusive Messages

Status

 

F0H

:System Exclusive

F7H

:EOX (End Of Exclusive)

Transmitted in the following three cases.

1.When Operating Bulk-Dump

2.If Exclusive of System MIDI is “P-Dump,” this unit transmits all parameters in the patch when the patch is changed.

3.If Exclusive of System MIDI is “TxEdit,” this unit transmits the parameter when the parameter is edited.

Refer to Section 3 to see details.

88

Page 88
Image 88
Roland VC-1 D-50 owner manual Midi Implementation, Data Transmission