INSTALLATION PARTS
Troubleshooting
No. | Error | Meaning | Remarks | |
Code | ||||
39 | E447 | Motor wire of Fan1 is not connected | Fan1 error | |
40 | E448 | Lock error on Fan1 of outdoor unit | Fan1 error | |
41 | E452 | Error due to ZCP detection circuit problem or | - | |
power failure | ||||
42 | E453 | Error due to overheated motor of outdoor unit's | Fan1 error | |
Fan1 | ||||
43 | E455 | Error due to overheated IPM of Fan1 | Fan1 error | |
44 | E458 | Fan speed error | Fan1 error | |
45 | E461 | Error due to operation failure of inverter compressor | - | |
46 | E462 | System stop due to full current control | - | |
|
|
| 1. Check if the service valve is open | |
|
|
| 2. Check for refrigerant leakage (pipe | |
|
|
| connection, pipe extension and | |
|
| Operation temperature protection of the top of | others) and charge refrigerant if | |
47 | E463 | necessary | ||
the compressor | ||||
3. Check the location of the outdoor unit | ||||
|
|
| ||
|
|
| and change the location if necessary | |
|
|
| 4. | |
|
|
| necessary | |
48 | E464 | IPM Over Current(O.C) | IPM | |
49 | E465 | Comp. Over load error | - | |
50 | E466 | Check AC Power and DC Link Voltage | ||
51 | E467 | Error due to abnormal rotation of the | Check Comp wire | |
compressor or unconnected wire of compressor | ||||
52 | E468 | Error on current sensor (Short or Open) | Check Outdoor Inverter PBA. | |
53 | E469 | Error on | - |
54E471 Outdoor EEPROM checksum error between MAIN Check Outdoor EEPROM PBA and INVERTER
55 | E472 | AC Line Zero Cross Signal out | - |
56 | E473 | Comp Lock error | - |
57 | E474 | Error on IPM Heat Sink sensor of inverter 1 | heck Outdoor Inverter PBA |
(Short or Open) | |||
58 | E475 | Error on inverter fan 2 | Fan2 error |
59 | E478 | Error due to overcurrent of Fan1 | Fan1 error |
72English