Samsung AF0AKV3SAEENSG manual Ipm

Models: AF0AKV3SAEENSG

1 80
Download 80 pages 33.41 Kb
Page 72
Image 72

INSTALLATION PARTS

Troubleshooting

No.

Error

Meaning

Remarks

Code

39

E447

Motor wire of Fan1 is not connected

Fan1 error

40

E448

Lock error on Fan1 of outdoor unit

Fan1 error

41

E452

Error due to ZCP detection circuit problem or

-

power failure

42

E453

Error due to overheated motor of outdoor unit's

Fan1 error

Fan1

43

E455

Error due to overheated IPM of Fan1

Fan1 error

44

E458

Fan speed error

Fan1 error

45

E461

Error due to operation failure of inverter compressor

-

46

E462

System stop due to full current control

-

 

 

 

1. Check if the service valve is open

 

 

 

2. Check for refrigerant leakage (pipe

 

 

 

connection, pipe extension and

 

 

Operation temperature protection of the top of

others) and charge refrigerant if

47

E463

necessary

the compressor

3. Check the location of the outdoor unit

 

 

 

 

 

 

and change the location if necessary

 

 

 

4. Re-install the outdoor unit if

 

 

 

necessary

48

E464

IPM Over Current(O.C)

IPM

49

E465

Comp. Over load error

-

50

E466

DC-Link voltage under/over error

Check AC Power and DC Link Voltage

51

E467

Error due to abnormal rotation of the

Check Comp wire

compressor or unconnected wire of compressor

52

E468

Error on current sensor (Short or Open)

Check Outdoor Inverter PBA.

53

E469

Error on DC-Link voltage sensor (Short or Open)

-

54E471 Outdoor EEPROM checksum error between MAIN Check Outdoor EEPROM PBA and INVERTER

55

E472

AC Line Zero Cross Signal out

-

56

E473

Comp Lock error

-

57

E474

Error on IPM Heat Sink sensor of inverter 1

heck Outdoor Inverter PBA

(Short or Open)

58

E475

Error on inverter fan 2

Fan2 error

59

E478

Error due to overcurrent of Fan1

Fan1 error

72English