Refrigerant charging

Allowable refrigerant pipe length and amount of additional refrigerant charging

Air purge refrigerant for piping is not filled in this product.

Make sure to vacuum inside of the connection pipe using vacuum pump after connecting pipes.

During initial installation, fill the additional refrigerant if the pipe length exceeds 5 m.

For every 1 m of exceeding pipe length, fill additional refrigerant as stated below.

Model

Refrigerant amount

Basic (g)

Additional (g/m)

 

AF80KV3SAEE*

6,600

50

AF0AKV3SAEE*

6,600

50

Ex) If total piping length is 30 m,

6,600g (standard filling amount for 5 m pipe): Factory default (AF0AKV3SAEE*)

1,250g = {50g/m x (30m-5m)}: Additional refrigerant amount (Fill during the installation)

7,850g: Total amount of refrigerant filling

Allowable refrigerant pipe length

Model name

Maximum allowable pipe length

Maximum height difference of the pipe

AF80KV3SAEE Series

75m

30m

AF0AKV3SAEE Series

 

 

INSTALLATION PARTS

54English

Page 54
Image 54
Samsung AF0AKV3SAEENSG manual Refrigerant charging, Allowable refrigerant pipe length