Pipe length between the indoor and the outdoor unit

If the pipe is lengthened, the performance of the unit is degraded, and the service life is shortened. Therefore, the pipe length should be as short as possible.

––Allowable pipe length: Maximum 75m

––Allowable pipe height difference:

When outdoor unit is installed higher level than indoor unit: Maximum 30m

When indoor unit is installed higher level than indoor unit: Maximum 20m

Choose a installation place where you can limit the pipe bending to less than 10.

Less than 20m

Indoor

unit

Outdoor

unit

Less than 30m

Outdoor

unit

Indoor

unit

Drilling a hole in the wall

Drill a hole of a 90mm in diameter at a less than 200mm in height from the bottom of the indoor unit in a slightly downward slope.

Indoor Outdoor

Less than Ø 90mm 200mm