SHR-4080P USER’S MANUAL

Quality

Recording resolution will be determined.

Choose one from Level 1(Low) to Level 8 (High). Level 8 supplies the best resolution

Rate

Determines Frame Rate to be recorded. Frame Rate means the number of screen recorded every second.

Set to 25ips, the system records too many screens per second and play continues intermittently since recording is more detailed. This is appropriate for concentrated monitoring zone setup.

25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips

Note

[Monitor Out]

You are not allowed to set up “25ips” of Rate and Video sized “Full D1” simultane- ously. The system does not support both at once.

PreAlarm

Pre Alarm Section

Event occurred point of time

Records the situation until Alarm is issued.

Off : No recording

3sec/ 5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue

PostAlarm

Post Alarm Section

Event occurred point of time

Records the situation since Alarm is issued.

Off : No recording

3sec/ 5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min : To this, the recording time after Alarm issue is set.

Alarm

Sensor State

Off : Sensor does not operate.

N.O(Normal Open) Sensor : Sensor remains open all the time and if closed, an

alarm will be issued. (A Contact)

N.C(Normal Close) Sensor : Sensor remains closed all the time and if open, an alarm will be issued. ( B Contact)

Cam

Determines a camera which will synchronize with the current sensor.

The default is currently set to the sensor number. A sensor shall be synchronized with at least a camera. Multi-synchronization is possible.

Alarm

Sensor

Sensor State

Cam

 

Alarm-Out

 

Beep-Out

 

1

 

N.O

 

 

 

 

 

1

 

 

 

None

 

10sec

 

2

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

10sec

 

 

 

CHO1

 

CHO2

 

CHO3

 

 

 

 

3

 

Off

 

CHO4

 

CHO5

 

CHO6

 

 

 

10sec

 

4

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

10sec

 

5

 

Off

 

CHO7

 

CHO8

 

All

 

 

 

10sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Off

 

 

 

OK

 

 

 

Cencel

 

 

10sec

 

7

 

Off

 

 

 

 

 

1

 

 

 

None

 

10sec

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

 

 

 

 

0

 

 

 

None

 

10sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

Alarm-Out

Arranges Alarm-Out when Alarm Sensor sounds.

At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to synchronize with the current sensor. Multi-choice is possible.

Beep-Out

Determines Alarm-Out Duration. Alarm-Out continues for the determined duration. Off/ 3sec/ 5sec/ 10sec/ 20sec/ 30sec/ 1min/ 2min

5-19

5-20

Page 35