MULTIMETER ALONE

Unit 5: Troubleshooting

TEST CHART

MODULE DIAL

CONNECTOR PIN

FUNCTION

 

 

 

 

1A

This test connector pin is used as the ground post.

 

 

 

 

2A

 

 

 

 

0

3A

Used to determine voltage of components that require between

+4.8 and +5.2 VDC to properly function.

 

 

 

 

 

1

4A

Used to determine voltage of components that require between

+11.4 and +12.6 VDC to properly function.

 

 

 

 

 

2

5A

Used to determine voltage of components that require between

-11.4 and -12.6 VDC to properly function.

 

 

 

 

 

3

6A

Used to determine voltage of components that require between

+23.5 and +24.5 VDC to properly function.

 

 

 

 

 

4

1B

Used in cunjunction with potentiometer VR2 to set the eye-mark

media sensor sensitivity.

 

 

 

 

 

5

2B

Used in cunjunction with potentiometer VR1 to set the gap or

center hole media sensor sensitivity.

 

 

 

 

 

6

3B

Used in cunjunction with potentiometer VR3 to set the ribbon

sensor sensitivity

 

 

 

 

 

7

4B

Used in cunjunction with potentiometer VR5 to set the edge-

hole media sensor sensitivity.

 

 

 

 

 

8

5B

Used in cunjunction with potentiometer VR6 to set the notched

tag media sensor sensitivity.

 

 

 

 

 

 

6B

Used in cunjunction with potentiometer VR7 to set jump sensor.

 

 

 

MULTIMETER ALONE

Testing of circuitry and sensor adjustment may be performed by using a multimeter without the assistance of the test module. To perform this task the multimeter probes must be attached to the correct connector pins of the test connector. Refer to the table above to correlate the desired testing or adjustment function with its relative connector pin. Afterward, refer to the table below to locate the required pins. Refer to the Adjustment Procedures chapter of the Operation unit for specific adjustment instructions if necessary and applicable.

6A

1A

6B

1B

Figure 5-2, Test Connector

SATO XL400-410e Operator Manual

PN 9001135A

Page 5-8