LD Language Elements

Use of Coils

Two coils are associated with the fast counter:

 

z coil TK1: Enable function input,

 

z coil RK1: Reset initial counter state input.

 

The use of these coils is described below.

 

Enable function input:

 

Symbol of the Enable Function Input coil of the fast counter:

 

 

 

 

 

 

 

 

 

TK1

 

 

 

 

 

 

 

 

 

 

This element is used to confirm the counter. When this coil is active, each pulse on

 

the I1 input will increment the Fast counter and each pulse on the I2 input will

 

decrement it.

 

 

 

Reset initial counter state input:

 

Symbol of the Reset Initial Counter State Input:

 

 

 

 

 

 

 

 

RK1

 

 

 

 

 

 

 

 

 

 

This input resets the counter function to its initial state.

 

Energizing the coil has the following effect:

 

z reset the current count value to zero if the count type is TO (up-counting from

 

 

the preset value).

 

z reset the current value to the preset value if the count type is FROM (down-

 

 

counting from the preset value).

 

Example: Counter reset by pressing on the Z1 key:

 

 

 

 

 

 

 

 

Z1

 

RK1

 

 

 

 

 

 

 

 

 

 

 

 

Each time the Z1 key is pressed, the counter is reinitialized.