LD Language Elements

Introduction

Description

In LD programming mode, an application can be created from the interface of the

 

front panel of the smart relay.

Here is detailed information on all possible elements of a ladder diagram in LD mode that are recognized and used by smart relays.

To better understand the functions performed by each element, where necessary a directly usable example is included.

Composition of

Smart relays accept 120-line diagrams.

Ladder Diagrams

z Each line is comprised of a maximum of 5 contacts.

 

zContacts must be attached to one coil, and the coil is not necessarily on the same line.

Note: When an application requires more than five contacts to activate an action, the auxiliary relays may be used.

Sample Ladder

Below is an example of a ladder diagram, as it appears on the display of the front

Diagram

panel of a smart relay:

I1

 

 

RT1

I2

 

 

 

I3

M3

Z1

SM1

 

 

 

TT1

 

 

 

Menu / OK

88

SR2MAN01 11/2007

Page 75