LD Language Elements

Deactivation of By default the Zx Keys are active. They may be deactivated in one of the following ways:

Zx Keysz From the smart relay front panel: Using : CONFIGURATION Zx KEYS menu, see Zx KEYS Menu, p. 62

zFrom the programming software: See on-line help of the programming software for more information.

Note: When the smart relay is in RUN mode, if the Zx Keys have been deactivated, they cannot be used for inputs in the program, but can be only used for navigating the menus.

Modification of

To modify a contact from the front panel of the smart relay (the programming window

the State of a

is displayed on the screen), simply:

Contact

z Place the mouse over the letter representing the contact,

 

z Proceed as indicated in the paragraph Modifying an element,, p. 44, to scroll

 

through the possible contact types (Z for a normally open contact, z for a normally

 

closed contact).

Initialization

 

Status of contacts on program initialization:

 

z Normally open mode (direct state) is inactive,

 

z Normally closed mode (reverse state) is active.

 

 

92

SR2MAN01 11/2007

Page 79
Image 79
Schneider Electric SR2MAN01 user manual Place the mouse over the letter representing the contact