Sharp AR-5320 X B. Misfeed in the fusing area, Push gently on both ends of the front cover

Models: AR-5316 AR-5316 X AR-5320 AR-5320 X

1 72
Download 72 pages 40.76 Kb
Page 52
Image 52
B. Misfeed in the fusing area

TROUBLESHOOTING

B. Misfeed in the fusing area

1 Push gently on both ends of the front cover.

2 Turn the roller rotating knob in the direction of the arrow.

Roller rotating kno1 Push gently on both ends of the front cover.b2 Turn the roller rotating knob in the direction of the arrow.5 Close the front cover and side cover.3 Carefully remove the misfed paper.

4 Lift the fusing unit release levers, to return them to their operating positions.

5 Close the front cover and side cover.

The misfeed indicator (Lower the fusing unit release levers to) will go out.

3 Carefully remove the misfed paper.

Lower the fusing unit release levers to

When closing the front cover, gently hold

allow easier removal.

Note

both ends.

When closing the side cover, press on the

 

 

Fusing unit

Be careful not to tear the

 

handle.

release lever

misfed paper during

If the misfeed indicator ( ) does not stop

 

removal.

 

blinking, check for torn pieces of paper in

 

 

 

the machine.

Warning

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or injury.

Caution

Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may damage the drum and cause smudges on copies.

Be careful about unfixed toner on the misfed paper not to soil your hands or clothes.

50

Page 52
Image 52
Sharp AR-5320 X, AR-5316 B. Misfeed in the fusing area, Push gently on both ends of the front cover, allow easier removal