Maintenance Indicators

The warning lights on the projector indicate problems inside the projector.

If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the projector will enter the standby mode. After the projector has entered the standby mode, follow the procedures given below.

Power indicator

Lamp indicator

Temperature warning indicator

About the temperature warning indicator

If the temperature inside the projector increases, due to blockage of the air vents, or the setting lo-

cation, “” will blink in the

lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the temperature warning indicator will blink, the cooling fan will run for further 90 seconds, then the pro-

jector will enter the standby mode. After “” appears, be sure to perform the following mea- sures.

About the lamp indicator

When the lamp ex-

ceeds 1,900 cumula- tive hours of use, “

will be displayed on the screen in yellow.

When the cumulative hours of use reach 2,000, “” will change to red, the lamp will automatically turn off and then the pro- jector will automatically enter the standby mode. At this time, the LAMP REPLACE- MENT indicator will illuminate in red.

If you try to turn on the projector a fourth time without replacing the lamp, the pro- jector will not turn on.

Maintenance indicator

Condition

Problem

Possible Solution

 

 

 

 

 

 

 

 

Normal

Abnormal

 

Blocked air intake

Relocate the projector to an area

Temperature

 

 

The internal

with proper ventilation.

 

 

 

 

 

 

Cooling fan break-

Take the projector to your nearest

warning

Off

Red on/

temperature is

down

Authorized SharpVision Service

 

 

 

indicator

 

Standby

abnormally high.

Internal circuit failure

Center or Dealer for repair.

 

 

 

 

 

 

 

 

 

Clogged air intake

Clean the ventilative holes accord-

 

 

 

 

 

ing to the procedure on page 77.

 

 

 

 

 

 

 

 

 

 

 

 

Carefully replace the lamp. (See

 

Blue on*

Red on/

The lamp does

Burnt-out lamp

page 81)

 

Blue

Standby

not illuminate.

Lamp circuit failure

Take the projector to your nearest

Lamp

blinks

Authorized SharpVision Service

 

 

 

indicator

when the

 

 

 

Center or Dealer for repair.

 

lamp is

Red

Lamp replace-

The lamp usage

Please exercise care when

 

active.

blinks

ment time.

time has exceeded

replacing the lamp.

 

 

 

 

1,900 hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Securely install the cover.

Power

Blue on*/

 

The power

 

If the power indicator blinks even

Red blinks

indicator blinks

The exhaust vent

when the exhaust vent cover is

indicator

Red on

in red when the

cover is open.

securely installed, contact your

 

 

 

 

projector is on.

 

nearest Authorized SharpVision

 

 

 

 

 

Service Center or Dealer for

 

 

 

 

 

advice.

 

 

 

 

 

 

 

* Blue is off when “LED” is set to “OFF”. (See page 67.)