Siemens 7ML19985AB01 instruction manual Fixed, Variable condition, Units

Models: 7ML19985AB01

1 112
Download 112 pages 47.88 Kb
Page 48
Image 48

P39

data logging rate

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

 

 

 

 

 

 

 

0

= 1 min

 

3 = 30

 

 

 

 

 

1

= 5

 

 

4 = 60

 

 

 

 

 

2

= 15

 

 

5 = 24 hr

 

 

 

 

 

 

 

 

variable (condition)

 

 

 

 

 

6

= 15/1 min (% flow / min)

19 = 60

/

1

(flow)

 

7 = 15 / 5

"

20 = 60 / 5

 

"

 

8

= 30 /

1

"

21

= 24 hr / 1 min

"

 

9

= 30 /

5

"

22

= 24 hr / 5 min

"

 

10

= 60

/ 1

"

23

= 24 hr / 15 min "

 

11

= 60

/ 5

"

24

= 15 /

1 min

(head)

 

12

= 24 hr / 1 min

"

25

= 15 /

5

 

"

 

13

= 24 hr / 5 min

"

26

= 30 /

1

 

"

 

14

= 24 hr / 15 min "

27

= 30 /

5

 

"

 

15

= 15

/ 1 min (flow)

28

= 60 /

1

 

"

 

16

= 15

/ 5

"

29

= 60 /

5

 

"

 

17

= 30

/ 1

"

30

= 24 hr / 1 min

"

 

18

= 30

/ 5

"

31

= 24 hr / 5 min

"

 

 

32 = 24 hr / 15 min "

P40

log rapid setpoint

 

 

P39 variable logging condition

units

 

% flow / min

% change of maximum flow per minute

 

flow

% of maximum flow

 

head

% of maximum head

P41

log normal setpoint

 

 

P39 variable logging condition

units

 

% flow / min

% change of maximum flow per minute

 

flow

% of maximum flow

 

head

% of maximum head

7ML19985AB01

OCM III

49

Page 48
Image 48