Siemens 7ML19985AB01 instruction manual U0 = crest width b, = constant

Models: 7ML19985AB01

1 112
Download 112 pages 47.88 Kb
Page 71
Image 71

RECTANGULAR WEIR (CONTRACTED), P3 = 8

‘U’ parameters required *

U0 = crest width b

*obtain from manufacturer’s specifications.

**calculated by OCM-3. May be viewed by accessing ‘U’ parameter.

Reference

ABSOLUTE CALCULATION, P4 = 0¤

For flows that can be calculated by the equation:

q = K x (b - 0.2h) x h1.5

where : q = flow rate h = head

K = constant

RATIOMETRIC CALCULATION, P4 = 1¤

For flows that can be calculated by the equation:

q = qcal x (b - 0.2h)/(b - 0.2hcal) x (h/hcal)2.5

where : q = flow rate

qcal = flow rate at maximum head h = head

hcal = maximum head

¤Refer to Operation \ Flow Calculation.

7ML19985AB01

OCM III