PALMER-BOWLUS FLUME *, P3 = 10

‘U’ parameters required **

U0 = maximum flume width, hmax

*typically those manufactured by Warminster or Plasti-Fab.

**obtain from manufacturer’s specifications.

Reference

RATIOMETRIC CALCULATION, P4 = 1¤

For flows that can be calculated by the equation:

q = qcal x f(h/hmax) / f(hcal/hmax)

where : q = flow rate

qcal = flow rate at maximum head h = head

hcal = maximum head

f(h/hmax) is determined by polynomial synthesis

¤Refer to Operation \ Flow Calculation.