SIMPLE EXPONENTIAL DEVICES, P3 = 0

TYPICAL SHARP-CRESTED WEIRS

transducer *

minimum 3 x h max

Typical Weir Profiles

V - notch or Triangular

U 0 = 2.5

Rectangular - suppressed

U 0 = 1.5

Trapezoidal (Cipolletti)

Sutro (Proportional)

U 0 = 1.5

U 0 = 1

 

(symmetrical or asymmetrical)

For rated flows under free flow conditions, the head is measured upstream of the weir plate at a minimum distance of 3 times the maximum head (i.e. where the liquid surface is not affected by drawdown).

*The transducer must be above the maximum head by at least the blanking value, P47.