Siemens 7ML19985AB01 Universal Head vs FLOW, P3 =, U0 = number of data points n, 4 to

Models: 7ML19985AB01

1 112
Download 112 pages 47.88 Kb
Page 79
Image 79

UNIVERSAL HEAD vs FLOW, P3 = 12

The flow curve is characterized by entering the head (Aeven) and flow (Aodd) ordinates for the number of data points (n, 4 to 16) over the flow range. The first point (A0,A1) generally being at 0 head and the last point (A2n-2,A2n-1) generally being at maximum head .

‘U’ parameters required *

U0 = number of data points (n, 4 to 16)

Aeven = head

Aodd = flow rate

*obtain from manufacturer’s specifications.

Reference

RATIOMETRIC CALCULATION, P4 = 1¤

For flows that can be calculated by the equation:

q = qcal x f(h)/f(hcal)

where : f(h) and f(hcal) are polynomials based on interpolation of data points

¤Refer to Operation \ Flow Calculation.

7ML19985AB01

OCM III

80

Page 79
Image 79
Siemens 7ML19985AB01 instruction manual Universal Head vs FLOW, P3 =, U0 = number of data points n, 4 to