Siemens 7ML19985AB01 instruction manual U0 = maximum listed head, hmax

Models: 7ML19985AB01

1 112
Download 112 pages 47.88 Kb
Page 77
Image 77

H-FLUME *, P3 = 11

‘U’ parameters required *

U0 = maximum listed head, hmax

*as developed by the U.S. Department of Agriculture, Soil Conservation Service.

**obtain from manufacturer’s specifications.

Reference

RATIOMETRIC CALCULATION, P4 = 1¤

For flows that can be calculated by the equation:

q = qcal x f(h/hmax)/f(hcal/hmax)

where : q = flow rate

qcal = flow rate at maximum head

f(h/hmax) and f(hcal/hmax) are determined by polynomial synthesis

¤Refer to Operation \ Flow Calculation.

7ML19985AB01

OCM III

78

Page 77
Image 77
Siemens 7ML19985AB01 instruction manual U0 = maximum listed head, hmax