Siemens E12 manual Industry Automation and Drive Technologies SCE Connect Menu

Models: E12

1 47
Download 47 pages 15.77 Kb
Page 11
Image 11

Industry Automation and Drive Technologies - SCE

"Connect" Menu:

The Ethernet IP mode has to be set to PNIO.

Place the cursor in front of Ports and press the OK button

Place the cursor in front of Ethernet and press the OK button

Place the cursor in front of IP Mode and press the OK button

Place the cursor in front of PNIO and press the OK button

The evaluation device now requests a restart; press the OK button to confirm.

After the restart, the red bus error LED (BF) flashes until communication is established by means of PROFINET between a controller and the VS120.

ESC may have to be pressed several times to get to the main menu.

All additional information for operating the evaluation device is provided in chapters 8.3, 8.4 and 9.2 of the operating instructions

“Image Processing Systems Vision Sensor SIMATIC VS120“.

TIA Training Document

Page 11 of 47

Module

E12

 

 

Status: 01/2010

Vision Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120

Page 11
Image 11
Siemens E12 manual Industry Automation and Drive Technologies SCE Connect Menu