Silex technology SX-550 manual Service Commands Description

Models: SX-550

1 83
Download 83 pages 42.77 Kb
Page 71
Image 71

Command

Description

Sample Output

Zero

Clears and resets the network statistic counters

Service Commands

Table 42 Service Commands

Command

Description

 

 

 

SET SERVI <service

Sets beginning of transmission (BOT) string index for service

name> BOT

The default value is 1.

 

 

Sample output:

 

 

SET SERVI <service name> BOT

nn

SET SERVI <service

Sets end of transmission (EOT) string index for service

name> EOT

The default value is 1.

 

 

Sample output:

 

 

SET SERVI <service name> EOT

nn

SH SERVI STRings

Defines the BOT and EOT strings used in services

[string_num]

If string_num is provided, then the specific string definition and expansion

 

 

display.

 

 

If string_num is not provided, then all string definitions display without their

 

expansions.

 

 

Sample output:

 

 

10: \FF\04\FF\05\FF\06\FF\08

 

SET SERVI <service

Sets filter index for service

 

name> FIlter

Sample output:

 

 

 

 

SET SERVI <service name> FIlter nn

SH SERVI FILters

Shows filter settings

 

 

Sample output:

 

 

#

Service Name

Filter

 

1

TWC_FFFFFF

0: No Filter

 

2

BINARY_P1

0: No Filter

 

3

TEXT_P1

1: Text Substitution m= LF, r= CRLF

 

4

TWC_FFFFFF_P1_4

0: No Filter

 

5

TWC_FFFFFF_P1_5

0: No Filter

 

6

TWC_FFFFFF_P1_AT

4: PostScript Tagged Binary

 

 

SET SERVI <service

Sets filter 1 text replacement match string index.

name> FMS

If the index is zero, the default string of <LF> (line feed) is used.

 

 

The default value is 0.

 

 

 

 

 

 

 

 

 

Console Commands

 

silex

Page 65

 

 

Part Number 40183-101

Page 71
Image 71
Silex technology SX-550 manual Service Commands Description