Silex technology SX-550 manual Serial Setting Parameters, Parameter Setting

Models: SX-550

1 83
Download 83 pages 42.77 Kb
Page 41
Image 41

Figure 17 Serial Settings Window

3. Configure the serial settings, as defined in Table 20.

 

Table 20 Serial Setting Parameters

 

 

Parameter

Setting

 

 

Mode

Sets the line mode or serial port protocol.

 

RS-232 provides an interface between data terminal equipment and

 

data communications equipment employing serial binary data

 

interchange over a wired connection with a maximum range of 50

 

feet (16.5 meters).

 

RS-422 provides a data transmission system using balanced

 

differential signals or voltages to send serial binary data over a

 

wired connection with a maximum range of 4,000 feet (1.2 km).

 

Sets the line mode or serial port protocol.

 

Values are:

 

232 (default), 422, Disabled

Character Bits

Sets the bits per character

 

Values are:

 

8 (default), 7

Parity

Sets parity checking to detect any errors in transmission.

 

Values are:

 

None (default), Even, Odd, Mark, Space

Speed

Sets the baud rate for measuring for data transmission speed

 

Values are:

 

9600 (default), 115200 (console port default) 300, 600,1200, 2400,

 

3600, 4800, 7200, 14400,19200, 38400, 57600, 76800, 230400,

 

460800, 921600