Silex technology SX-550 manual Port Monitor Alert Commands Description, Show Port S1 Trigmon

Models: SX-550

1 83
Download 83 pages 42.77 Kb
Page 50
Image 50

￿

Configuring Serial Port Monitor Alert and Trap Configuration

The SX-550 module can be configured to scan and compare the data received on the serial port to user- defined strings. A match with a string can be a source for SNMP traps and/or email alerts.

The match strings and corresponding email or web page message strings are configured from the Internal Configuration Console interface.

Table 28 describes the Monitor Alert and Trap Configuration Commands.

Table 28 Port Monitor Alert Commands

Command

Description

SHOW PORT S1 TRIGMON

Shows strings and index numbers being monitored

SET PORT S1 TRIGMON <trig #> <string>

Assigns a string to be monitored on the serial port

Example:

Local> show port s1 trigmon

Index # Monitor String

------ --------------

Local> set port s1 trigmon 0 trigger on seeing this string

Local> show port s1 trigmon

Index # Monitor String

------ --------------

0:trigger on seeing this string