B
ASIC
C
ONFIGURATION
3-29
flash. (Range: 0-7, Default: 3)
RAM Level – Limits log messages saved to the switch’s temporary
RAM memory for all levels up to the specified level. For example, if
level 7 is specified, all messages from level 0 to level 7 will be logged to
RAM. (Range: 0-7, Default: 7)
Note:The Flash Level must be equal to or less than the RAM Level.
Web – Click System, Logs, System Logs. Specify System Log Status, set
the
level of event messages to be logged, and click Apply.
Level Argument Level Description
debugging 7 Debugging messages
informational 6 In formational messages only
notifications 5 Normal but significant condition, such as cold
start
warnings 4 Warning conditions (e.g., return false,
unexpected return)
errors 3 Error conditions (e.g., invalid input, default
used)
critical 2 Critical conditions (e.g., memory allocation, or
free memory error - resource exhausted)
alerts 1 Imm ediate action needed
emergencies 0 System unusable