B
ASIC
C
ONFIGURATION
3-33
error .
Resetting the System
Web – Click System, Reset. Click the Reset button to restart the switch.
CLI – Use the reload command to restart the switch.
Note:When restarting the system, it will always run the Power-On
Self-Test.
Setting the System Clock
Simple Network Time Protocol (SNTP) allows the switch to set its internal
clock based on periodic updates from a time server (SNTP or NTP).
Maintaining an accurate time on the switch enables the system log to
record meaningful dates and times for event entries. You can also manually
set the clock using the CLI. (See “calendar set” on page3-7 6.) If the clock
is not set, the switch will only record the time from the factory default set
at the last bootup.
This switch acts as an SNTP client in two modes:
Unicast – The switch periodically sends a request for a time update to a
configured time server. You can configure up to three time server IP
Console#show logging flash3-63
Syslog logging: Enable
History logging in FLASH: level errors
[0] 0:0:5 1/1/1 "PRI_MGR_InitDefault function fails."
level: 3, module: 13, function: 0, and event no.: 0
Console#show logging ram3-63
Syslog logging: Enable
History logging in RAM: level debugging
[0] 0:0:5 1/1/1 PRI_MGR_InitDefault function fails."
level: 3, module: 13, function: 0, and event no.: 0
Console#
Console#reload3-30
System will be restarted, continue <y/n>?