Constituent Menus of the COLOR TEMP ADJ Menu

This section describes the functions of the constituent menus of the COLOR TEMP ADJ menu.

Notes

The menu numbers (A, B1, C11 and so on) are not displayed on the monitor screen.

For details of menu numbers, see page 20.

An arrow (÷) following the description of an item or setting in each menu indicates another menu which appears or an operation which is executed when you select that menu item or setting. If the description of an item or setting is not followed by an arrow, it indicates that selecting the item or setting finishes the setting operation.

[B]COLOR TEMP ADJ menu

Select STD, COL1, COL2, or CH SET. ÷[B1] STD: Use common data (factory setting: D65). COL1: Use common data (factory setting: D93). COL2: Use common data (factory setting: D56/

D651)).

CH SET: Use data for each individual channel (factory setting: D65). Use the numeric keypad to select the desired channel.

[B1] STD/COL1/COL2/CH SET menu

Select the adjustment method.

MANUAL...: Set with the MANUAL knob. ÷ [B11]

PROBE...: Set using a probe. ÷[B12]

COPY...: Copy data from elsewhere. ÷[B13]

TRIM...: Perform fine adjustments after setting the color temperature. ÷[B14]

[B11] MANUAL menu

Set the following data necessary to perform knob adjustment and select ADJUST.

ADJUST...: Adjust the gain and bias. To shift between gain adjustment and bias adjustment, press the UP or DOWN button. Use the appropriate knob for each adjustment as described below. After the adjustment, press the ENTER button to confirm the adjusted values.

RED: CONTRAST knob (Adjust the R gain or bias with the CONTRAST knob.)

GREEN: BRIGHT knob (Adjust the G gain or bias with the BRIGHT knob.)

BLUE: CHROMA knob (Adjust the B gain or bias with the CHROMA knob.)

LUMINANCE: PHASE knob (Adjust luminance with the PHASE knob.)

To reset RED/GREEN/BLUE to the value before adjustment

When you are adjusting the gain or bias using the MANUAL adjustment knobs, you can reset the setting to the one before adjustment by pressing the corresponding MANUAL button.

To reset all the settings at the same time, press the PHASE button.

Note

You cannot reset the setting after you press the ENTER button.

ORIGINAL VALUE...: Set the initial value. STD: Use common data (factory setting: D65). COL1: Use common data (factory setting: D93). COL2: Use common data (factory setting: D56/

D651)).

SIGNAL: Select the white signal to be used for adjustment.

INT: Use an internal signal. Simultaneously with the adjustment of the gain and bias, the 100 IRE and 20 IRE signals are automatically switched.

EXT: Use an external input signal. When adjusting the gain and bias, input the proper signal.

2 Chapter Menus

...........................................................................................................................................................................................................

1)D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U

D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E