Setting the Channel Selection Method and Power- Up Conditions — SYSTEM CONFIGURATION Menu

2 Chapter Menus

Overview

The SYSTEM CONFIGURATION menu is used for the following settings:

(1) Channel number entry method

Select a method to enter channel numbers using the ten-key pad, from two options.

(2) Power-up condition

This menu sets the condition of the monitor when the MAIN POWER switch on the rear panel is switched on.

(3) Power-up input channel

Specify the channel to be selected automatically when the power is turned on.

(4) Time from power-up until degauss

If several monitors are turned on at the same time and all start degaussing at the same time, there will be a very large current draw on the power supply for a few moments. To prevent this, the delay time between power-up and degaussing can be set for each monitor independently.

(5)AFC time constant

(6)Residual subcarrier detection (when using the BKM-24N/25P)

It is possible to detect residual subcarrier signals from phase change by setting the adaptor’s residual subcarrier switch on.

(7)Auto chroma control (ACC) (when using the BKM-27T)

(8)Holding the current contrast/brightness setting after white balance adjustment

(9)Making a shortcut to a white balance adjustment menu

Make the [F2] key a shortcut key to display the COLOR TEMP ADJ MANUAL menu. This allows you to jump directly to the MANUAL menu display corresponding to the color temperature setting (STD/ COL 1/COL 2) for the currently displayed image.

Structure of the SET UP Menu [C] / SYSTEM CONFIGURATION Menu [C4]

 

 

 

 

 

 

 

 

Level 1

 

 

Level 2

 

 

 

 

 

 

 

INPUT CONFIGURATION C1

 

 

 

 

 

REMOTE C2

 

 

 

 

 

PASSWORD C3

 

 

 

 

 

SYSTEM CONFIGURATION C4

 

 

 

INPUT SELECT

 

 

 

 

ON SCREEN SET C5

 

 

STANDBY MODE

 

 

 

ALIGNMENT C6

 

 

DEFAULT CH

 

 

 

EXTEND MENU C7

 

 

DEGAUSS DELAY

 

 

 

 

 

 

 

AFC TIME

 

 

 

 

 

 

 

 

 

 

RESIDUAL SC SW

 

 

 

 

 

 

 

 

 

 

ACC SW

 

 

 

 

 

 

 

 

 

 

CONT/BRT HOLD

 

 

 

 

 

 

 

 

 

 

COL TEMP SHORT-CUT

 

 

 

 

 

 

 

 

 

 

 

 