Specifications

General

System

525 lines, 60 fields per second

 

interlaced

 

625 lines, 50 fields per second

 

interlaced

CRT

Super fine pitch Trinitron

 

BVM-20F1U/20F1E/20E1U/

 

20E1E

 

Aperture grille pitch: 0.3 mm

 

(BVM-20F1U/20F1E) or

 

0.25 mm (BVM-20E1U/

 

20E1E), 90 degree deflection,

 

30.6 mm diameter in-line gun.

Effective picture size:

387291 mm (15 1/4

111/2 inches) (w/h)

483 mm (19 1/8 inches) (diagonal size)

CRT protection: EHT (extremely high tension) protection type Warm-up time: approx. 30 minutes

Anode voltage: 27 kV with no beam current

Nominal chromaticity coordinates:

SMPTE phosphor (BVM-20F1U/

20E1U)

 

x

y

 

 

 

R

0.630

0.340

 

 

 

G

0.310

0.595

 

 

 

B

0.155

0.070

 

 

 

Error: less than ±0.005

EBU phosphor (BVM-20F1E/20E1E)

 

x

y

 

 

 

R

0.640

0.330

 

 

 

G

0.290

0.600

 

 

 

B

0.150

0.060

 

 

 

Error: less than ±0.005

BVM-14F1U/14F1E/14E1U/ 14E1E//14F5U/14F5E/14E5U/ 14E5E

Aperture grille pitch: 0.25 mm (BVM-14F1U/14F1E/14F5U/ 14F5E) or 0.22 mm (BVM- 14E1U/14E1E/14E5U/14E5E), 90-degree deflection, 29.4 mm diameter in-line gun.

Effective picture size: 267 200 mm (10 5/8

7 7/8 inches) (w/h)

331 mm (13 1/8 inches) (diagonal size)

CRT protection: EHT (extremely high tension) protectiontype Warm-up time: approx. 30 minutes

Anode voltage: 25 kV with no beam current

Nominal chromaticity coordinates:

SMPTE phosphor (BVM-14F1U/

14E1U)

 

x

y

 

 

 

R

0.630

0.340

 

 

 

G

0.310

0.595

 

 

 

B

0.155

0.070

 

 

 

EBU phosphor (BVM-14F1E/14E1E)

 

x

y

 

 

 

R

0.640

0.330

 

 

 

G

0.290

0.600

 

 

 

B

0.150

0.060

 

 

 

Power requirements

100 to 240 V AC, 10%, 50/60 Hz Power consumption

BVM-20F1U/20F1E/20E1U/ 20E1E: 120 W

When an optional adaptor is installed: 200 W

BVM-14F1U/14F1E/14E1U/ 14E1E: 110 W

When an optional adaptor is installed: 145 W

BVM-14F5U/14F5E/14E5U/ 14E5E: 110 W

When an optional adaptor is installed: 175 W

Peak inrush current

(1)Power ON, current probe method:

55A (240V) (BVM-20F1E/20E1E/14F5E/ 14E5E/14F1E/14E1E)

(2)Hot switching inrush current, measured in accordance with European standard EN55103-1: 50A (230V) (BVM-20F1E/ 20E1E), 38A (230V) (BVM-14F5E/14E5E/ 14F1E/14E1E)

3 Chapter Appendix

3 Chapter

Appendix

57