Adjusting the Color Temperature — COLOR TEMP ADJ Menu

Overview

The color temperature is adjusted with the COLOR TEMP ADJ menu. The color temperature can be set either commonly to all channels or individually for each channel.

The adjusted value can then be used as an original value.

Color temperature adjustment can be made in the following three ways:

(1) Knob adjustment

Adjust the color temperature with the bias and gain knobs.

(2)Automatic adjustment using a probe You can use the following probes for automatic adjustment of color temperature. Except for the Sony BKM-14L, a cable is required to connect the probe to the monitor.

Manufacturer

Probe Model Name

 

 

SONY

BKM-14L (no cable required)

 

 

MINOLTA

CA-100

 

 

GRASEBY

SLS 9400

 

 

PHILIPS

PM 5639

 

 

THOMA

TF6

 

 

(3) Copying other data

Copying data from other channels, common data, other BVM-series monitors that have been connected via the serial remote connector, or from data stored in monitor memory cards.

2 Chapter Menus

For details of the required cables, see page 60.