2 Chapter
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
To access the MANUAL menu directly | START: Start adjustment. ÷[B12111] |
When the [F2] button is assigned as the | X: Enter the x coordinate. |
key to the MANUAL menu, you can directly | Y: Enter the y coordinate. |
access the MANUAL menu that corresponds to the | LOW LIGHT (20IRE): Enter the brightness (cd/m2) |
color temperature setting set to the image on the | for low light. |
screen. | HIGH LIGHT (100IRE): Enter the brightness (cd/ |
| m2) for high light. |
For details of how to assign the | D65: Use D65 setting. |
“Setting the | D93: Use D93 setting. |
CONFIGURATION Menu” on page 42. |
|
Menus
[B12] PROBE menu
Select the probe for color temperature adjustment. SONY
[B122]
MINOLTA
PHILIPS PM 5639...: Use the PM 5639. ÷[B122]
THOMA TF6...: Use the TF6. ÷[B122]
•If you cannot execute an ADJUST or ANALYZE menu operation when using the Sony
•When using the Thoma TF6 probe, set the TF6 PRINT menu to off.
[B121] SONY
Select the
ADJUST...: Perform automatic color temperature adjustment. ÷[B1211]
ANALYZE: Display readout values on the screen.
÷[B1212]
[B1211] ADJUST menu
To start adjustment, proceed as follows.
When you use the previously adjusted values for adjustment, you can make start adjustment by selecting START without perform operations step (1) and step
(2).
(1)Select either D65 or D93.
Rather than selecting D65 or D93, you may instead enter the values of the CIE 1931 color system x and y coordinates.
(2)Enter values for LOWLIGHT and HIGHLIGHT.
(3)Select START.
[B12111] START menu
The following message appears. Perform operation according to the message to start adjustment.
SET PROBE ON CRT
PRESS ENTER
Adjustment starts when the probe is placed against the center of the screen and the ENTER button is pressed.
[B1212] ANALYZE menu
The following message appears. Perform operation according to the message to enable the
SET PROBE ON THIS CRT
PRESS ENTER
Attach the
Once the calibration has been carried out, you can use the probe to analyze the monitor’s performance.
[B12121] ANALYZE menu
Display color temperature and luminance readout values from the
X:xxxx: Display the color temperature x coordinate value.
Y:xxxx: Display the color temperature y coordinate
value.
L:xxxx: Display the luminance value.
[B122] GRASEBY/MINOLTA/PHILIPS/THOMA menu
The contents and function of this menu are the same as those of the ADJUST menu [B1211] .
[B13] COPY menu
Select the source to be copied from.
OTHER VALUE...: Copy data from another channel or from common data. ÷[B131]
OTHER MONITOR...: Copy data from another monitor. ÷[B132]
MEMORY CARD...: Copy data from a memory card. ÷[B133]