[B131] OTHER VALUE menu:
Select one of the following. ÷Copy is carried out. STD: Copy common data (factory setting: D65). COL1: Copy common data (factory setting: D93). COL2: Copy common data (factory setting: D56/
D651)).
CH SET: Copy data from a particular channel (factory setting: D65). Enter the number of the channel from which the data will be copied. When the input channel number is deleted with the Del button. the number “1” appears instead. Restore the previous setting by pressing the MENU button, then
D65: Copy the color temperature of D65.
D93: Copy the color temperature of D93.
[B132] OTHER MONITOR menu
Input the address of the monitor from which the data will be copied.
MONITOR ADDRESS: Input the address of the monitor from which the data will be copied. ÷ [B1321]
[B1321] MONITOR ADDRESS menu
Select STD, COL1,COL2, or CH SET. ÷Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/ D651)).
CH SET: Copy data from a particular channel (factory setting: D65). Enter the number of the channel from which the data will be copied.When the input channel number is deleted with the Del button. the number “1” appears instead. Restore the previous setting by pressing the MENU button, then
[B133] MEMORY CARD menu Select the file name. ÷[B1331]
[B1331] FILE NAME menu
Select STD, COL1, COL2,or CH SET of the memory card data. ÷Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/ D651)).
CH SET: Copy data from a particular channel (factory setting: D65). Enter the number of the channel from which the data will be copied. When the input channel number is deleted with the Del button. the number “1” appears instead. Restore the previous setting by pressing the MENU button, then
[B14] TRIM menu
Trim the original setting by selecting ADJUST. ADJUST: Adjust the gain and bias. To shift between
gain adjustment and bias adjustment, press UP/ DOWN buttons. Use appropriate knobs in each adjustment as described below. After the adjustment, press the ENTER button to confirm the adjusted values.
RED: CONTRAST knob (Adjust the R gain or bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or bias with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance with the PHASE knob.)
To reset RED/GREEN/BLUE to the value before adjustment
When you are adjusting the gain or bias using the MANUAL adjustment knobs, you can reset the setting to the one before adjustment by pressing the corresponding MANUAL button.
To reset all of settings at the same time, press the PHASE button.