9Alarm terminals
For input and output of various alarm and timing signals. The COM terminals are all for ground.
|
| NON REC OUT |
| WARNING OUT | ||||
| ALARM |
| CLOCK |
| ||||
| RESET |
|
|
|
|
| ALARM | |
COM IN | OUT | COM IN OUT | FULL FULL |
ALARM FULL terminal
FULL terminal
WARNING OUT terminal
CLOCK terminals
NON REC OUT terminal
ALARM terminals
ALARM terminals
For signals that can be triggered for alarm recording IN: Alarm signal input
The output level drops to 0 V when the
NON REC OUT terminal (5V DC/5.7 Ωk)
The output level drops to 0 V if recording is interrupted.
CLOCK terminals
You may adjust the
IN: Clock input
OUT: Clock output (5V DC/5.7 kΩ ). The output level drops to 0 V at the time you specified by menu operation.
WARNING OUT terminal (5V DC/5.7 Ωk)
The output level drops to 0 V if any problem occurs with the HDD or fan.
FULL terminal (5V DC/5.7 Ωk )
The output level drops to 0 V if the remaining capacity of the normal recording area of the
ALARM FULL terminal (5V DC/5.7 Ωk)
The output level drops to 0 V if the remaining capacity of the alarm recording area of the
0Control terminals
For input and output of various control signals. The COM terminals are for ground.
RS485 terminals
REMOTE terminal
SERIES terminals
SW OUT terminal
COM | COM COM IN OUT COM COM | |
A | B REMOTE | SW OUT |
SERIES
RS485 RS485
TERMINATE
ON
OFF
RS485 TERMINATE switch
RS485 terminals
For an
For the connections, see “Remote Control Connections and Associated Settings” on page 41(GB).
REMOTE terminals
For remote control.
For the connections, see “Remote Control Connections and Associated Settings” on page 41(GB).
SERIES terminals
To connect the control signal in series when connecting video and audio signals for multiple HSR- X200/X200P units in series.
IN: Connect to the OUT terminal of the previous
OUT: Connect to the IN terminal of the next HSR- X200/X200P unit.
SW OUT terminals (5V DC/5.7 Ωk )
For pulse signal output. By connecting to SW of a multiplexer, you may control the timing to switch the input picture.
RS485 TERMINATE switch
For
qa All Reset button
For CPU reset
15 (GB)