9Alarm terminals

For input and output of various alarm and timing signals. The COM terminals are all for ground.

 

 

NON REC OUT

 

WARNING OUT

 

ALARM

 

CLOCK

 

 

RESET

 

 

 

 

 

ALARM

COM IN

OUT

COM IN OUT

FULL FULL

ALARM FULL terminal

FULL terminal

WARNING OUT terminal

CLOCK terminals

NON REC OUT terminal

ALARM terminals

ALARM terminals

For signals that can be triggered for alarm recording IN: Alarm signal input (normally-open contact) RESET:Alarm reset input (normally-open contact) OUT: Sensor alarm signal output (5V DC/5.7 k).

The output level drops to 0 V when the built-in activity detection sensor operates or an external alarm is detected.

NON REC OUT terminal (5V DC/5.7 k)

The output level drops to 0 V if recording is interrupted.

CLOCK terminals

You may adjust the built-in clock using an external switch or synchronize the clocks of other connected devices to the clock of this unit.

IN: Clock input (normally-open contact). Connect an external switch or equivalent.

OUT: Clock output (5V DC/5.7 k). The output level drops to 0 V at the time you specified by menu operation.

WARNING OUT terminal (5V DC/5.7 k)

The output level drops to 0 V if any problem occurs with the HDD or fan.

FULL terminal (5V DC/5.7 k )

The output level drops to 0 V if the remaining capacity of the normal recording area of the built-in hard disk drops below the specified value (default: 1%).

ALARM FULL terminal (5V DC/5.7 k)

The output level drops to 0 V if the remaining capacity of the alarm recording area of the built-in hard disk drops below the specified value (default: 1%).

0Control terminals

For input and output of various control signals. The COM terminals are for ground.

RS485 terminals

REMOTE terminal

SERIES terminals

SW OUT terminal

COM

COM COM IN OUT COM COM

A

B REMOTE

SW OUT

SERIES

RS485 RS485

TERMINATE

ON

OFF

RS485 TERMINATE switch

RS485 terminals

For an RS-485 interface. Connect to the A, B, and COM (ground) pins of a controller using a twisted-pair cable.

For the connections, see “Remote Control Connections and Associated Settings” on page 41(GB).

REMOTE terminals (resistor-alley system)

For remote control.

For the connections, see “Remote Control Connections and Associated Settings” on page 41(GB).

SERIES terminals

To connect the control signal in series when connecting video and audio signals for multiple HSR- X200/X200P units in series.

IN: Connect to the OUT terminal of the previous HSR-X200/X200P unit.

OUT: Connect to the IN terminal of the next HSR- X200/X200P unit.

SW OUT terminals (5V DC/5.7 k )

For pulse signal output. By connecting to SW of a multiplexer, you may control the timing to switch the input picture.

RS485 TERMINATE switch

For RS-485 termination. When connecting multiple HSR-X200/X200P units in series via the RS485 terminals, set this switch of the last HSR-X200/X200P unit to ON.

qa All Reset button

For CPU reset

15 (GB)