Alarm Recording

The HSR-X200/X200P automatically starts alarm recording when it detects the specified trigger. For the trigger, you can select the following alarm signals independently or in combination:

1.External alarm input

2.Internal alarm generated by the built-in activity detection sensor when it detects a change in luminance at the specified points on the camera input picture.

By activating pre-alarm recording, the HSR-X200/ X200P continues recording the camera input, overwriting the data for the specified duration. When the trigger is detected, the HSR-X200/X200P switches to regular alarm recording. This enables you to check the image a certain time before the trigger is actually detected.

Note

When a multiplexer is in use, you can only select external alarm input for the trigger and must select a certain channel (camera number) to be recorded.

For channel selection, see “Multiplexer Channel Selection” on page 33(GB).

Settings for Alarm Recording

For alarm recording, you may set the following requirements, including the trigger.

Use ALARM REC MODE SET of MAIN MENU 1.

 

<ALARM REC

MODE SET>

PICTURE QUALITY

 

 

: SUPER

FRAME/FIELD RECORDING

 

: FIELD

AUDIO

RECORDING

 

 

: ON

ALARM

RECORDING

 

 

: MODE1

REC CYCLE :

0.33

SEC, DURATION : 40 SEC

PRE-ALARM RECORDING

 

: ON

REC CYCLE : A

0.05

SEC, DURATION : 1 MIN

 

c (1010 ALARMS CAN BE RECORDED)

ALARM

TRIGGER

 

 

: ALARM AND SENSOR

ACTIVITY SENSOR

 

c

 

 

 

 

 

PICTURE QUALITY

FRAME/FIELD RECORDING

AUDIO RECORDING ON/OFF

REC CYCLE

These items can be set the same as for normal recording.

ALARM RECORDING

Select the mode to execute alarm recording. MODE1: To execute alarm recording regardless of

timer recording

MODE2: To execute alarm recording only while timer recording is in progress

MODE3: To execute alarm recording only while timer recording is not in progress

MODE4: To execute alarm recording during the period(s) set for timer recording (timer recording itself is not performed)

Set to OFF when no alarm recording is required.

DURATION

Set the duration for alarm recording.

You may select from among 1S/2S/5S/10S/20S/40S/ 1M/2M/3M/4M/5M/10M/15M/CC.

With CC, recording is made as long as the alarm signal is ON.

PRE-ALARM RECORDING

To perform pre-alarm recording, set PRE-ALARM RECORDING to ON, and select REC CYCLE and DURATION of pre-alarm recording.

For the duration, you may select from among 1S/2S/ 10S/20S/40S/1M/2M/3M/4M/5M/10M/15M.

Note

You cannot highlight PRE-ALARM RECORDING on the display with ALARM RECORDING set to OFF.

ALARM TRIGGER

Select the trigger.

ALARM: External alarm input

SENSOR: Internal alarm generated by the built-in activity detection sensor

ALARM AND SENSOR: Simultaneous occurrence of external and internal alarms

ALARM OR SENSOR: Occurrence of either an external or internal alarm

Setting procedure

1 Press the MENU button to display MAIN MENU 1 on the monitor screen.

2 Turn the Jog dial to highlight 8. ALARM REC MODE SET and turn the Shuttle dial clockwise.

The ALARM REC MODE SET display appears.

24 (GB)