Locations and Functions of Parts
7Channel (camera) number
8 Operation status
9 Remaining of recording area
4CH z 100%
2 Time | 6 Alarm count |
| 5 Recording cycle |
1 Date | 4 Picture quality |
| 3 Alarm type |
By pressing the EXIT/OSD button on the front panel, you can change the display position or even make them disappear.
Items 1 to 6 can be independently turned on/off with DISPLAY/VIDEO LOSS SET of MAIN MENU 2.
1Date/2Time
In a recording mode or stop status (monitoring the camera input), the current date
In playback, the date and time when the recording has made are displayed.
3Alarm type
The active alarm type is displayed.
ALARM: Alarm recording
4Picture quality/5Recording cycle
In a recording mode or stop status, the picture quality and recording cycle specified for normal recording are displayed.
In playback, the picture quality and recording cycle when the recording has made are displayed.
6Alarm count
Each time alarm recording is made, the value is increased by one.
The value will return to 1 if it exceeds 9999.
7Channel (camera) number
When a multiplexer whose channel information can be decoded is connected, the camera number you selected is displayed.
8Operation status
The current operation mode is displayed. z: Recording
B: Playback
X: Still
M: Variable speed playback in the forward direction
m: Variable speed playback in the reverse direction
9Remaining of recording area
When the recording area OVERWRITE function is set to OFF with the RECORDING CONDITIONS SET menu (page 47(GB)), the remaining capacity of the recording area is displayed (in %).
16 (GB)