The total value of the areas must be 99%.

The percentage of the archive area is automatically calculated (in the range of 1 to 15 % according to the values of the normal recording and the alarm recording areas.

A confirmation message is displayed.

5 To execute the change, select YES and turn the Shuttle dial clockwise.

To cancel, select NO.

Resetting an area

You may clear all the data in an area by a reset operation.

Notes

The normal and alarm recording areas can be reset only when the OVERWRITE function (see the next paragraph) is OFF.

You cannot delete specific events only.

1 Highlight the AREA FULL RESET line of the area you wish to reset on the RECORDING AREA SET display and turn the Shuttle dial clockwise.

A confirmation message appears.

2 To execute the reset, select YES and turn the Shuttle dial clockwise.

To cancel, select NO.

Overwriting a recording area

For the normal recording and alarm recording areas, you can set whether to overwrite the data or stop recording when the area becomes full.

Use RECORDING CONDITIONS SET of MAIN MENU 1.

You may also set the warning status when the remaining capacity of a recording area becomes close to the end.

1 Press the MENU button to display MAIN MENU 1.

2 Select 4. RECORDING CONDITIONS SET.

The RECORDING CONDITIONS SET display appears, displaying the current settings.

<RECORDING CONDITIONS SET>

SERIES RECORDING

: OFF

NORMAL RECORDING AREA

 

OVERWRITE

: OFF

ALARM RECORDING AREA

 

OVERWRITE

: OFF

REMAINING DISK WARNING

: 1%

3 Turn the Jog dial to highlight the OVERWRITE line of the area to be set and turn the Shuttle dial clockwise.

The current setting (default: OFF) flashes.

4 To overwrite, set OVERWRITE to ON and turn the Shuttle dial clockwise.

Changing the percentage to warn the remaining

When OVERWRITE is OFF, the FULL or ALARM FULL indicator on the front panel will flash and an alarm signal will be output from the FULL or ALARM FULL terminal if the remaining capacity of the normal or alarm recording area drops to a certain percentage. This value is set to 1% in the default setting.

You can change it on the RECORDING CONDITIONS SET display.

1 Turn the Jog dial to highlight the REMAINING DISK WARNING line and turn the Shuttle dial clockwise.

The current setting (default: 1) flashes.

2 Turn the Jog dial to set the desired value and turn the Shuttle dial clockwise.

The value can be selected in the range of 1 to 10%.

When the settings are completed Press the EXIT/OSD button to exit the menu.

47 (GB)