TANDBERG 7000 MXP
Supported DVI cables:
TANDBERG supports
It is possible to extend existing DVI cables by the use of extension cables. The maximum cable length however, is 5 meters. Going beyond that may result in quality loss.
Pin | Signal | Pin | Signal | Pin | Signal |
| Assignment |
| Assignment |
| Assignment |
1 | T.M.D.S. | 9 | T.M.D.S. | 17 | T.M.D.S. Data0- |
| Data2- |
| Data1- |
|
|
2 | T.M.D.S. | 10 | T.M.D.S. | 18 | T.M.D.S. Data0+ |
| Data2+ |
| Data1+ |
|
|
3 | T.M.D.S. | 11 | T.M.D.S. | 19 | T.M.D.S. |
| Data2/4 Shield |
| Data1/3 Shield |
| Data0/5 Shield |
4 | T.M.D.S. | 12 | T.M.D.S. | 20 | T.M.D.S. Data5- |
| Data4- |
| Data3- |
|
|
5 | T.M.D.S. | 13 | T.M.D.S. | 21 | T.M.D.S. Data5+ |
| Data4+ |
| Data3+ |
|
|
6 | DDC Clock | 14 | +5V Power | 22 | T.M.D.S. Clock |
|
|
|
|
| Shield |
7 | DDC Data | 15 | Ground (return | 23 | T.M.D.S. Clock+ |
|
|
| for +5V, HSync |
|
|
|
|
| and VSync) |
|
|
8 | Analog Vertical | 16 | Hot Plug Detect | 24 | T.M.D.S. Clock- |
| Sync |
|
|
|
|
C1 | Analog Red | C2 | Analog Green | C3 | Analog Blue |
C4 | Analog | C5 | Analog Ground |
|
|
| Horizontal |
| (analog, R, G & |
|
|
| Sync |
| B return) |
|
|
The TANDBERG Profile systems are shipped with a PC cable with integrated audio:
222