TANDBERG 700 MXP user manual Using CSU adapter, Connecting to Adtran T1 ESF CSU ACE

Models: 700 MXP

1 307
Download 307 pages 30.22 Kb
Page 278
Image 278

TANDBERG 7000 MXP

6.8 Appendix 8

(Not available on all TANDBERG systems)

Connecting the system to PRI/T1

Using CSU adapter

Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection. The E1/T1-interface must be connected to a CSU approved according to IEC 60950, UL 1950 or equivalent standard. The PRI- line will run the AT&T 4ESS, 5ESS and National ISDN protocols in addition to Euro ISDN (E1).

Connecting to Adtran T1 ESF CSU ACE

Connect the PRI cable from the system to the input marked CPE (Customer Provided Equipment) on the Adtran CSU (straight through category 5 cable is recommended). Connect to the network via the NET connector on the Adtran CSU.

Configuration of the system

Open the Administrator Settings Menu from the Control Panel and select Network.

Choose Network Type: PRI and specify your PRI number, max. Channels, cable length (between system and CSU) and switch type.

Configuration of Adtran T1 ESF CSU ACE

ƒEnter 2)CONFIG menu using SCROLL and ENTER buttons.

ƒEnter 3)TERMINAL menu. Check 1)FORMAT:ESF, 2)CODE: B8ZS , 3)SET LBO: 0-133 (corresponding to Cable Length setting on the system).

ƒGo to main menu and enter 1)NETWORK menu. 7)SET LBO: 0.0 (according to information from Telco).

ƒAlso, other network parameters should be set according to information from your Telco.

264

Page 278
Image 278
TANDBERG 700 MXP user manual Using CSU adapter, Connecting to Adtran T1 ESF CSU ACE, Configuration of the system