Connecting the system to PRI/T1
Using CSU adapter
Connecting the system to the ISDN network via the
Connecting to Adtran T1 ESF CSU ACE
Connect the PRI cable from the system to the input marked CPE (Customer Provided Equipment) on the Adtran CSU (straight through category 5 cable is recommended). Connect to the network via the NET connector on the Adtran CSU.
Configuration of the system
Open the Administrator Settings Menu from the Control Panel and select Network.
Choose Network Type: PRI and specify your PRI number, max. Channels, cable length (between system and CSU) and switch type.
Configuration of Adtran T1 ESF CSU ACE
Enter 2)CONFIG menu using SCROLL and ENTER buttons.
Enter 3)TERMINAL menu. Check 1)FORMAT:ESF, 2)CODE: B8ZS , 3)SET LBO:
Go to main menu and enter 1)NETWORK menu. 7)SET LBO: 0.0 (according to information from Telco).
Also, other network parameters should be set according to information from your Telco.