All balanced inputs and outputs (A and B) use balanced line signals according to V.11 (RS422) and single ended signals in accordance with V.10 (RS423).

For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal B.

For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to GND.

Cable length max: 50 meter

5.1.4Data port

The data port(s) are implemented as Data Communications Equipment (DCE). The connector used are female 9-pin D-subs.

The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides 12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.

 

Signal name

 

Direction

 

Pin

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

Carrier detect, CD

 

From

1

 

 

 

 

DCE

 

 

 

 

 

 

 

 

 

 

 

Receive data,

 

From

2

 

 

RXD

 

DCE

 

 

 

 

 

 

 

 

 

 

 

Transmit data,

 

To DCE

3

 

 

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

Data terminal

 

From

4

 

 

ready, DTR

 

DCE

 

 

 

 

 

 

 

 

 

 

 

Signal ground,

 

 

5

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

Data set ready,

 

From

6

 

 

DSR

 

DCE

 

 

 

 

 

 

 

 

 

 

 

Ready to send,

 

To DCE

7

 

 

RTS

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear to send,

 

From

8

 

 

CTS

 

DCE

 

 

 

 

 

 

 

 

 

 

 

Ring indicator, RI

 

From

9

 

 

 

 

DCE

 

 

 