Connecting to the codec

Accessing XACLI Codec C90

Contents

Introduction

Getting Started

Interfaces

System Integrator Guide

 

AboutAboutthetheAPIAPI

xConfiguration

xCommand

xStatus

Cameras

Appendices

Contact us

 

 

 

 

 

 

 

 

Connecting to the codec

Accessing XACLI

XACLI can be accessed through Telnet and SSH via the LAN interface or through the COM port by connecting a serial cable to the serial interface connector, referred to as the COM port.

The COM port (RS-232) is a 9-pin, female, D-sub connector located on the back of the TANDBERG Codec C90. See the illustration to the right.

The port is configured as a DCE (Data Communications Equipment). The COM port (RS-232) is default set to 38400 baud, 8 data bits, none parity and 1 stop bit from factory. The port may also be referred to as the Data port.

Telnet/SSH login

Telnet is by default disabled. This can be changed with a configuration command: xConfiguration NetworkServices Telnet Mode: On/Off

xConfiguration NetworkServices Telnet Mode: On

Telnet/SSH login

User name is: admin

Default password is: TANDBERG

Serial port login

The serial port is password protected by default. The password protection may be configured.

User name is: admin

Default password is: TANDBERG

The COM Port at TANDBERG Codec C90

Line in

Serial port configurations

On the serial port the baud rate and password protection may be configured.

The configuration command for the baud rate is:

xConfiguration SerialPort BaudRate: <9600/19200/38400/115200>

xConfiguration SerialPort BaudRate: 38400

The configuration command for login required is: xConfiguration SerialPort LoginRequired: <On/Off>

xConfiguration SerialPort LoginRequired: On

Reboot. The system requires a reboot for the changes to baud rate and password protection to take effect.

Note: When system boots up the baud rate of the boot messages is 38400 regardless of the baud rate set in the codec application.