Command Descriptions
2–274 TDS Family Oscilloscope Programmer Manual
% 
" 
$
"
"
("'#"

%!
#%!
" corresponds to the Isolated +1 on the front panel menu. This is the
default value.
" corresponds to the Isolated –1.
%! corresponds to Eye Diagram.
 
selects the AMI pulseform to the Isolated +1.
TRIGger:MAIn:COMMunication:AMI:THReshold:HIGH
TDS 500C & 700C Only
Sets or queries the AMI communication trigger’s high threshold value in volts.
Trigger
%"("'#"&#  
%"("'#"&# 
% 
" 
$
("'#"

&# 


 is the high value of the threshold. The unit of measure is volts. The
default is +0.5 volts.
 2.8 E–2
sets the high threshold to 28 milliVolts.
Arguments
Examples
Group
Syntax
Arguments
Examples