All installations and services must be performed by qualified service personnel.

Table 2: Burner Specifications and High and Low Fire Heating Performance

 

Oil Pump

Oil

Heat Input

Heat

 

 

 

Heating

Flowrate @

Output

Burner Model

Air Tube

Nozzle

Pressure

Rate*

Mode

(PSIG)

Nozzle

(BTUH)

Rate**

Number

Combination

Type

 

(GPH)

(BTUH)

 

 

 

 

 

 

 

 

 

High Fire

130

2 0.75

105,000

85,000

 

 

Simplex, 80

 

 

 

 

 

AFG-TP1502

AF42 BNHSSS

deg., hollow

 

 

 

 

 

Low Fire

120

1 0.6

85,000

67,000

 

 

cone

*Based on #2 fuel (domestic heating) oil having higher heating value of 140,000 BTU per gallon.

**Based on an assumed steady state, thermal efficiency of 80%.

1Factory installed.

2Provided by installer.

For more specific burner information, consult the Model AFG Oil Burner Instruction Manual or contact Thermo Products, LLC. P.O. Box 217, North Judson, IN 46366. Phone no. 574-896-2133.

18

Page 19
Image 19
Thermo Products 36)- 80, OPB (24, 30 service manual Oil Pump