All installations and services must be performed by qualified service personnel.
Yes
IS IGNITION ESTABLISHED?
No
ARE THE ELECTRODES | No | IS IGNITION TRANSFORMER | No | REPLACE IGNITION |
ARCING? |
| CAPABLE OF PRODUCING A |
| TRANSFORMER |
| 3/4" ARC? (10,000 VAC) |
| ||
|
|
|
|
| Yes |
|
|
Yes | DETERMINE IF THE ELECTRODES ARE |
ALIGNED, CONTACT SPRINGS TOUCHING | |
| ELECTRODE RODS, & PORCELAIN |
| INSULATORS CLEAN AND |
| UNCRACKED. ADJUST OR REPLACE, |
| AS NECESSARY. |
Yes
IS THE OIL PUMP | No | IS THE COUPLING BETWEEN | No |
| |
REPLACE PUMP | |||||
OPERATING? |
| THE BURNER MOTOR AND |
| ||
| THE PUMP STRIPPED? |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Yes | ||
|
|
| Yes |
|
|
|
| ||||
|
|
| REPLACE COUPLER |
| |||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
| |
| IS OIL AVAILABLE TO THE BURNER? |
|
| VERIFY ALL OIL VALVE(S) ARE OPEN, | |||||||
|
|
|
| ||||||||
|
|
|
| OIL TANK IS SUFFICIENTLY FULL, | |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| AND OIL LINE CONTAINS OIL. | |
|
|
|
|
|
|
|
|
|
|
|
|
FURNACE OPERATES FOR |
|
| No |
|
|
|
| ||||
COMPLETE CYCLE? |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
Yes
BURNER RUN NORMAL | No |
| IS HEAT ANTICAPATOR SET | No | MEASURE MILLIAMPS BETWEEN 'W' &'R' | |||||||
| TO MILLIAMP SETTING |
| ON THE T'STAT SUBBASE AND SET HEAT | |||||||||
|
|
|
|
|
| |||||||
CYCLE? |
| MEASURED ON SUBBASE? |
|
| ANTICIPATOR ACCORDINGLY | |||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
|
|
|
| |
| Yes |
|
| IF PROBLEM PERSISTS CONTINUE TO NEXT SECTION. |
| |||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
BLOWER RUNS
NORMAL CYCLE?
No | IS TEMPERATURE RISE | No |
|
|
|
Yes
CHECK FAN ON & OFF (DIP SWITCH)
SETTINGS ON FAN CONTROL
AND RETURN AIR TEMPERATURE
79