Manual background

All installations and services must be performed by qualified service personnel.

Yes

IS IGNITION ESTABLISHED?

No

ARE THE ELECTRODES

No

IS IGNITION TRANSFORMER

No

REPLACE IGNITION

ARCING?

 

CAPABLE OF PRODUCING A

 

TRANSFORMER

 

3/4" ARC? (10,000 VAC)

 

 

 

 

 

 

Yes

 

 

Yes

DETERMINE IF THE ELECTRODES ARE

ALIGNED, CONTACT SPRINGS TOUCHING

 

ELECTRODE RODS, & PORCELAIN

 

INSULATORS CLEAN AND

 

UNCRACKED. ADJUST OR REPLACE,

 

AS NECESSARY.

Yes

IS THE OIL PUMP

No

IS THE COUPLING BETWEEN

No

 

REPLACE PUMP

OPERATING?

 

THE BURNER MOTOR AND

 

 

THE PUMP STRIPPED?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

Yes

 

 

 

 

 

 

 

REPLACE COUPLER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

IS OIL AVAILABLE TO THE BURNER?

 

 

VERIFY ALL OIL VALVE(S) ARE OPEN,

 

 

 

 

 

 

 

 

OIL TANK IS SUFFICIENTLY FULL,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND OIL LINE CONTAINS OIL.

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE OPERATES FOR

 

 

No

 

 

 

 

COMPLETE CYCLE?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

BURNER RUN NORMAL

No

 

IS HEAT ANTICAPATOR SET

No

MEASURE MILLIAMPS BETWEEN 'W' &'R'

 

TO MILLIAMP SETTING

 

ON THE T'STAT SUBBASE AND SET HEAT

 

 

 

 

 

 

CYCLE?

 

MEASURED ON SUBBASE?

 

 

ANTICIPATOR ACCORDINGLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

Yes

 

 

IF PROBLEM PERSISTS CONTINUE TO NEXT SECTION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER RUNS

NORMAL CYCLE?

No

IS TEMPERATURE RISE

No

 

 

 

Yes

CHECK FAN ON & OFF (DIP SWITCH)

SETTINGS ON FAN CONTROL

CHECK-BLOWER SPEED

AND RETURN AIR TEMPERATURE

79

Page 80
Image 80
Thermo Products 30, OPB (24, 36)- 80 service manual