Thermo Products 36)- 80, OPB (24, 30 service manual

Models: 30 36)- 80 OPB (24

1 91
Download 91 pages 61.55 Kb
Page 79
Image 79
Manual background

All installations and services must be performed by qualified service personnel.

TURN THERMOSTAT TO CALL FOR HEAT

DOES THERMOSTAT MAKE CONTACT?

Yes

No

IS ROOM TEMPERATURE

BELOW THERMOSTAT SETTING?

Yes

CHECK IN PUT POWER,

DISCONNECTING SWITCH,

AND FUSE(S), IF EQUIPPED.

No IS ROOM TEMPERATURE No

Yes

ALLOW THE ROOM

AIR TO COOL

TURN T'STAT SETTING

ABOVE ROOM

TEMPERATURE

Yes

DOES BURNER MOTOR

 

 

 

 

START?

 

 

 

 

No

 

 

 

CHECK FOR LINE VOLTAGE

 

 

 

 

@ FAN CONTROL MODULE.

 

 

 

 

IF NOT 115 VAC, CHECK FOR

IS VOLTAGE PRESENT

No

IS THE BURNER

No

BLOWN FUSE OR TURN ON

AT BURNER MOTOR?

 

PRIMARY LOCKED

 

POWER. IF 115 VAC PRESENT,

 

OUT ON SAFETY ?

 

CHECK OUT FAN CONTROL

 

 

 

 

 

 

 

MODULE & PRIMARY MODULE

 

 

 

 

ACCORDING TO MANUFACTURER'S

 

 

Yes

 

INSTRUCTIONS.

 

 

 

 

Yes

 

 

 

 

 

 

PUSH IN PRIMARY RESET BUTTON

 

IS BURNER MOTOR RESET

No

IS THE OIL PUMP

No

REPLACE BURNER

BUTTON POPPED OUT

 

MECHANICALLY

 

MOTOR

 

LOCKED-UP?

 

 

 

 

 

Yes

Yes

 

PUSH IN MOTOR RESET BUTTON

REPLACE OIL PUMP

 

78

Page 79
Image 79
Thermo Products 36)- 80, OPB (24, 30 service manual