MAINTENANCE
MAINTENANCE
RECOMMENDED FILLING INSTRUCTIONS FOR HYDRAULIC RESERVIORS
When filling or checking the oil level, the unit should be parked on a level surface., shut ”OFF”, and allow sufficient time to cool to ambient temperature. Use caution when removing the pressurized breather. Do not place face over opening when removing breather.
If your reservoir has two sight glasses: The reservoir should be filled to the top of the lower sight glass on the side of the tank. Do not
If your reservoir has one sight glass/temperature gage: The reservoir should be filled to the center of the sight glass on the side of the tank. Do not over- fill. If the tank has too much oil, the excess may be expelled through the pressurized breather.
REPLACEING IN-TANK HYDRAULIC FILTER:
Loosen the four bolts on the top cover of the filter housing. Turn cover
Side and Rear Flail | Maintenance Section |