22. SURVEILLANCE I/O CONNECTOR FUNCTIONS

The rear panel Surveillance I/O connector* permits "Speaker Line Reference Impedance Measurement (Initial Setting)" and "Speaker Line Check" to be enabled and monitored by connected external equipment. Referring to the pin arrangement and functions, prepare the matching D-sub male connector (screw-lock type) for connection to the external equipment. (See p. 11 No. 41 SURVEILLANCE I/O connector.)

* Requires installation of the optional SV-200M Surveillance Board.

SV-200M's D-sub female connector

13 SURVEILLANCE I/O 1

Locking nut: 4-40 UNC

2514

SURVEILLANCE I/O connector pin function table

Pin

 

 

Signal name

IN

Signal/logic

Function/status

No.

 

 

/OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Zone 1 short

OUT

Active Low

Zone 1 speaker line is shorted.

 

 

 

 

 

 

 

 

 

2

Zone 1 Disconnection

OUT

Active Low

Zone 1 speaker line is disconnected.

 

 

 

 

 

 

 

 

 

3

Zone 2 short

OUT

Active Low

Zone 2 speaker line is shorted.

 

 

 

 

 

 

 

 

 

4

Zone 2 Disconnection

OUT

Active Low

Zone 2 speaker line is disconnected.

 

 

 

 

 

 

 

 

 

5

Zone 3 short

OUT

Active Low

Zone 3 speaker line is shorted.

 

 

 

 

 

 

 

 

 

6

Zone 3 Disconnection

OUT

Active Low

Zone 3 speaker line is disconnected.

 

 

 

 

 

 

 

 

 

7

Zone 4 short

OUT

Active Low

Zone 4 speaker line is shorted.

 

 

 

 

 

 

 

 

 

8

Zone 4 Disconnection

OUT

Active Low

Zone 4 speaker line is disconnected.

 

 

 

 

 

 

 

 

 

9

Zone 5 short

OUT

Active Low

Zone 5 speaker line is shorted.

 

 

 

 

 

 

 

 

 

10

Zone 5 Disconnection

OUT

Active Low

Zone 5 speaker line is disconnected.

 

 

 

 

 

 

 

 

 

11

Ground fault

OUT

Active Low

Some of speaker lines are grounded.

 

 

 

 

 

 

 

 

 

12

Power amplifier failure

OUT

Active Low

Power amplifier is faulty.

 

 

 

 

 

 

 

 

 

13

Setting/checking busy

OUT

Active Low

During measurement of the speaker line

 

 

 

 

 

 

 

 

reference impedance (Initial setting) or during

 

 

 

 

 

 

 

 

check of the speaker lines.

 

 

 

 

 

 

 

 

 

14

Initial setting error

OUT

Active Low

The speaker line reference impedance

 

 

 

 

 

 

 

 

couldn't be measured successfully.

 

 

 

 

 

 

 

 

(The measured impedance exceeds the

 

 

 

 

 

 

 

 

expected range or is unstable.)

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

Not used.

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Speaker line check

IN

One-shot make

Check of the speaker line impedance starts.

 

activation

 

 

 

 

 

 

 

 

 

 

 

 

24

Speaker line initial

IN

One-shot make

Measurement of the speaker line reference

 

setting activation

 

 

impedance (Initial setting) starts.

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

Not used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

Page 47
Image 47
TOA Electronics VM-2120 Surveillance I/O Connector Functions, Surveillance I/O connector pin function table