Notes to Users

Network Planning Information

 

 

Step 4: Network Planning Information

4-1. Strata CT Tone Plan.

Table A3 below lists the characteristics of the tones and signals used in Strata CT.

Table A3

Tones/Signal to:

Frequency

 

Cadence

Meaning

Exchange Line

Music On Hold

N/A

Call on Hold

DKT

500/640Hz

1s

On 3s Off

I/C PSTN call Opt.1.

 

modul.10Hz

1s

On 3s Off

I/C PSTN call Opt.2.

 

1300/1780Hz

1s

On 3s Off

I/C PSTN call Opt.3.

 

modul.10Hz

1s

On 3s Off

I/C PSTN to Busy DKT

 

860/1180Hz

1s

On 3s Off

I/C Int call

 

modul.10Hz

0.6s On 1000Hz/0.6s On 800Hz

Call from D/phone A

 

2000Hz mod by 10Hz

0.6s On 1000Hz/0.6s 800Hz

Call from D/phone B

 

500Hz

0.7s On 660Hz/0.7s On 500Hz

Call from D/phone B

 

1000/800Hz

1s

On 3s Off

Busy/DND Override

 

1000/800Hz

 

 

 

 

660/500

 

 

 

 

2000Hz

 

 

 

2 Wire extns

20Hz

1s

On 3s Off

Ring Signal

 

DTMF A

80 or 160mS

Voice Mail Answer

 

DTMF D

80 or 160mS

Voice Mail Disconnect

 

DTMF B

80 or 160mS

Voice Mail Recall

 

MWI Signal

0.9 ON/0.1s Off

Message Waiting Signal

Tie Lines

400Hz

0.375s On/0.375s Off

Extension Busy

 

350/440Hz

Continuous

Dial Tone

 

400/450Hz

0.4 On/0.2s Off/0.4s On/2s Off

Ring Tone

 

400HZ

0.375s On/0.375s Off

Delay Busy Tone

DISA calls

400Hz

0.375s On/0.375s Off

Extension Busy

 

350/440Hz

Continuous

Dial Tone

 

4000/450Hz

0.4 On/0.2s Off/0.4s On/2s Off

Ring Tone

 

400Hz

0.375s On/0.375s Off

Delay Busy Tone

Internal general

350/400Hz

Continuous

Dial Tone

 

400/450Hz

0.4 On/0.2s Off/0.4s On/2s Off

Ringing Tone

 

400Hz

0.375s On/0.375s Off

Extension Tone

 

400Hz

0.375s On/0.375s Off

NU/Reorder Tone

 

400Hz

1s

On

Executive override

4-2. System Port to Port losses.

Strata CT ACD Supervisor November 2001

29

Page 37
Image 37
Toshiba Digital Business Telephone Solutions manual Network Planning Information