Toshiba RAM-SM800AT-E, RAM-SM800KRT-E minute protection function, Warm air control, Defrosting

Models: RAM-SM560BT-E RAM-SM560KRT-E RAM-SM800UT-E RAM-SM800AT-E RAM-SM560UT-E RAM-SM800BT-E RAM-SM560AT-E RAM-SM800KRT-E

1 110
Download 110 pages 17.63 Kb
Page 92
Image 92

Cleaning the air inlet grille

1. Remove the air inlet grille.

Hold the both sides of the air inlet grille and open upward.

Move the center arm to the left and remove the grille.

2. Wash it with water using a soft sponge or towel. (Do not use metallic scrubbing brush or other hard brushes.)

Use of such hard objects will cause scratches on the surface of the air inlet grille, and the coating to peel off.

If very dirty, clean the air inlet grille with a neutral detergent, and rinse it off with water after removing it

from the unit.

3. Wipe out water from the air inlet grille and dry.

4.Fit the left and right arms of the air inlet grille to the shafts on the two sides of the air conditioner and push in completely, and then push in the center arm.

5. Check that the center arm has been completely inserted and close the air inlet grille.

• Push the arrow locations (four) at the bottom of the air inlet grille to check whether the grille is completely closed.

AIR CONDITIONER OPERATIONS AND PERFORMANCE

3 minute protection function

A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is turned on. This will protect the machine.

Heating operation characteristics

Preheating operation

The air conditioner will not deliver warm air immediately after it is started.

Warm air flows out after approximately 5-minutes when the indoor heat exchanger warms up. (The PRE.-DEF. lamp is on during the preheating operation.)

Warm air control

When the room temperature reaches the set temperature, the indoor fan speed is automatically reduced to prevent cold draft.

The outdoor unit will stop.

Defrosting

If the outdoor unit is frosted during heating operation, defrosting is started automatically (for approximately 5 to 10 minutes). To maintain the heating effect, the PRE.-DEF. lamp is on.

The fans on the indoor and outdoor units stop during the defrost operation.

During defrost operation, defrosted water drains from the bottom plate of the outdoor unit.

89

Page 92
Image 92
Toshiba RAM-SM800AT-E minute protection function, Heating operation characteristics Preheating operation, Warm air control