8 ELECTRICAL WORK
For the air conditioner that has no power cord.
NOTE:
For selection and connection method of the power supply cords, refer to the details in the Installation Manual of the outdoor unit.
CAUTIONS
• | If incorrect/incomplete wiring is carried out, it |
| may cause an electrical fire or smoke. |
• | Prepare the power supply for exclusive use with |
| the air conditioner. |
• | Be sure to use the cord clamps specified |
| positions with attached to the product. |
• | Do not damage or scratch the conductive core |
| and inner insulator of power and |
| cables when peeling them. |
• | Be sure to comply with local cords on running |
| the wire from outdoor unit to indoor unit (size of |
| wire and wiring method etc.) |
1.Connect the wires between the units correctly. Errors made in the connections can result in the unit malfunctioning.
2.Connect the control wires between the outdoor unit and indoor unit as shown in the figure below :
Air inter grille
Front panel
2
1
Cord clamp
• Use the power cord and |
with specified thickness, specified type, and |
protective devices specified. |
Terminal cover
Screw
Earth line
Connecting cable
How to wire
1.Connect the connecting cable to the terminal as identified with their respective matched numbers on the terminal block of indoor and outdoor unit.
H07
2.Insulate the unsheathed redundant cords (conductors) with electrical insulation tape. Process them so that they do not touch any electrical or metal parts.
3.For
|
| 10 | 1 | 2 | 3 |
|
|
|
|
| 10 |
1 | 2 | 3 |
|
|
|
|
|
|
|
| |
|
| 60 |
|
| 50 |
|
|
|
|
|
Earth line | Connecting |
| cable |
Screw