1 6 OVEN MODES
Accessing the Fault Count Screen | 3. To change the display language. | |
Refer to page 29 for fault descriptions. | 4. To access the info screen. | |
| ||
From the CONFIG MODE (Figure 9, page 15), | To access the SETUP MODE, press the up key | |
from the OVEN OFF or COOLING DOWN MODE | ||
press R1 to access the fault count screen (Figure | ||
(to access the CONFIG MODE), and then press L1. | ||
13). The oven will display the number of faults | ||
| ||
that have occurred since the oven fault counts |
| |
were last cleared (page 20), the oven’s software | Changing the Display Temperature | |
was last updated (page 15), or the oven was last | The oven can display the temperature in either | |
returned to the manufacturer’s default settings | ||
Celsius or Fahrenheit units. To change the | ||
(page 20). | display temperature, press L1 in SETUP MODE | |
| (Figure 14). |
Accessing the Setup Mode
From the CONFIG MODE (Figure 9, page 15), press L1 to access the SETUP MODE. The SETUP MODE allows the user to customize several oven settings - see below for more details.
Accessing the Test Mode
From the CONFIG MODE (Figure 9, page 15), press R3 to access the TEST MODE. The TEST MODE gives the service agent the ability to diagnose oven problems and perform other serv- ice related tasks. See page 17 for more informa- tion on the TEST MODE.
Setup Mode
Figure 14
The SETUP MODE serves four main purposes:
1.To change the display temperature.
2.To access the edit option screen.
Edit Option Screen
The edit option screen (Figure 16) allows the user to switch between full edit, rigid, and flex options. For more information on the different edit options, see Editing a Cooking Profile on page 12.
To access the edit option screen,
1.Press L3 (Figure 14) to access the password screen (Figure 15).
2.Input the password 6 6 3 3 by pressing the soft key adjacent to the appropriate number.
To change the edit option (Figure 16),
L1 | FAULT | COUNTS | R1 | L1 | 1 |
| 4 | R1 |
F1: 0 | F6: 0 | ENTER PASSWORD | ||||||
| F2: 0 | F7: 0 |
|
|
|
|
| |
|
|
|
| <6633> |
|
| ||
L2 | F3: 0 | F8: 0 | R2 | L2 | 2 | 5 | R2 | |
F4: 0 | F9: 0 |
| ||||||
|
|
|
|
|
|
| ||
| F5: 0 | F10: 0 |
|
|
|
|
|
|
L3 |
|
| R3 | L3 | 3 |
| 6 | R3 |
Figure 13: Fault Counts Screen |
|
| Figure 15: Password Screen |
|
|
L1 | DEGS F | ENGLISH |
L2 | SETUP MENU |
|
|
| |
L3 | EDIT/RIGID/FLEX | INFO |
R1 | L1 | FULL EDIT* |
| R1 |
R2 | L2 |
| EDIT OPTION | R2 |
RIGID |
| |||
R3 | L3 | FLEX |
| R3 |