Turbo Chef Technologies 3240 Setup Mode, Accessing the Fault Count Screen, Edit Option Screen

Models: 3240

1 92
Download 92 pages 62.2 Kb
Page 34
Image 34
Accessing the Fault Count Screen

1 6 OVEN MODES

Accessing the Fault Count Screen

3. To change the display language.

Refer to page 29 for fault descriptions.

4. To access the info screen.

 

From the CONFIG MODE (Figure 9, page 15),

To access the SETUP MODE, press the up key

from the OVEN OFF or COOLING DOWN MODE

press R1 to access the fault count screen (Figure

(to access the CONFIG MODE), and then press L1.

13). The oven will display the number of faults

 

that have occurred since the oven fault counts

 

were last cleared (page 20), the oven’s software

Changing the Display Temperature

was last updated (page 15), or the oven was last

The oven can display the temperature in either

returned to the manufacturer’s default settings

Celsius or Fahrenheit units. To change the

(page 20).

display temperature, press L1 in SETUP MODE

 

(Figure 14).

Accessing the Setup Mode

From the CONFIG MODE (Figure 9, page 15), press L1 to access the SETUP MODE. The SETUP MODE allows the user to customize several oven settings - see below for more details.

Accessing the Test Mode

From the CONFIG MODE (Figure 9, page 15), press R3 to access the TEST MODE. The TEST MODE gives the service agent the ability to diagnose oven problems and perform other serv- ice related tasks. See page 17 for more informa- tion on the TEST MODE.

Setup Mode

Figure 14

The SETUP MODE serves four main purposes:

1.To change the display temperature.

2.To access the edit option screen.

Edit Option Screen

The edit option screen (Figure 16) allows the user to switch between full edit, rigid, and flex options. For more information on the different edit options, see Editing a Cooking Profile on page 12.

To access the edit option screen,

1.Press L3 (Figure 14) to access the password screen (Figure 15).

2.Input the password 6 6 3 3 by pressing the soft key adjacent to the appropriate number.

To change the edit option (Figure 16), -Press L1 to select the full edit option. -Press L2 to select the rigid option. -Press L3 to select the flex option.

L1

FAULT

COUNTS

R1

L1

1

 

4

R1

F1: 0

F6: 0

ENTER PASSWORD

 

F2: 0

F7: 0

 

 

 

 

 

 

 

 

 

<6633>

 

 

L2

F3: 0

F8: 0

R2

L2

2

5

R2

F4: 0

F9: 0

 

 

 

 

 

 

 

 

 

F5: 0

F10: 0

 

 

 

 

 

 

L3

 

 

R3

L3

3

 

6

R3

Figure 13: Fault Counts Screen

 

 

Figure 15: Password Screen

 

 

L1

DEGS F

ENGLISH

L2

SETUP MENU

 

 

 

L3

EDIT/RIGID/FLEX

INFO

R1

L1

FULL EDIT*

 

R1

R2

L2

 

EDIT OPTION

R2

RIGID

 

R3

L3

FLEX

 

R3

Figure 14: Setup Mode

Figure 16: Edit Option Screen

Page 34
Image 34
Turbo Chef Technologies 3240 manual Setup Mode, Accessing the Fault Count Screen, Changing the Display Temperature